70 20 20 94

Levering 1-3 hverdage

Høj kvalitet til lave priser

Sikker betaling

ProTec 100


{{amount}}

Technical data ProTec 100

Impact test

Acceptance test: TB 21 + TB 41
Test date: 03.05.2011
Containment level: T1/T 3
Test location: TÜV Süd, Munich
Minimum installation length: 137 m
Ground anchoring: no

System description

Material: steel and concrete
Height: 0,56 m
Element length: 6,00 m
Structural width: 0,25 m
Planning width: 0,12 m
Weight per m: 124 kg

Test conditions

Test vehicle: car 1,3 t; impact angle 8°; 80 km/h
  truck 10 t; impact angle 8°; 70 km/h

Test results

T3: dyn. deflection 0,55 m + structural width 0,25 m = 0,8 m (corresponds to effective range W2)
ASI value: 0,2 (A)
T1: dyn. deflection 0,25 m + structural width 0,25 m = 0,5 m (corresponds to effective range W1)
ASI value: 0,2 (A)

Test reports

Test reports ProTec 100: BASt 2011 7E 56
Test reports reflektor element: BASt V4-64/2010

 

Kontakt os på 70 20 20 94