Technical data ProTec 80

Impact test

Acceptance test: TB 21 + TB 41 TB 11 + TB 42
Test date: 29. + 30.11.16 01. + 02.12.2016
Containment level: T 1 + T 3 H 1
Test location: Aldenhoven Aldenhoven
Testlength: 156 m 156 m
Ground anchoring: no yes (only starter element)

System description

Material: steel and concrete
Height: 0,50 m
Element length: 6,00 m
Structural width: 0,24 m
Planning width: 0,12 m
Weight per m: 80 kg

Test conditions

Acceptance test: TB 21 /TB41 TB 11 /TB42
Test vehicle: car/truck, Weight: 1,3 t / 10 t, car/truck, Weight: 8°/8°,
Speed: 80 km/h / 70 km/h
car/truck, Weight: 0,9 t / 10 t, car/truck, Weight: 20°/15°,
Speed: 100 km/h / 70 km/h

Effective range

Containment level Effective range Structural width ASI Value
T 1 W 1 0,24 m A
T 3 W 2 0,24 m A
H 1 W 6 0,24 m A

Test report No.

Test reports ProTec 80 for T3 / T1: F16480601 / F16480602
Test reports ProTec 80 for H1: F16480603 / F16480604
Test No. reflector element: BASt V4-64/2010

Kontakt os på 70 20 20 94